The freight in your cold room has a deadline the power doesn't know about

A dark store loses a day of sales. A dark cold room loses the inventory, the temperature record and, if the record can't be produced, the ability to sell what survived.
MCS maintains critical power, standby generation and thermal systems for distribution centers, cold storage facilities and multi-site retail estates.

Three different clocks running at once

Refrigeration runs on a thermal clock. A cold room doesn't fail when the power drops - it fails when it crosses the top of its allowable range, which might be hours later. That delay is why refrigeration outages get under-treated: the alarm goes off and nothing appears to be wrong yet. What matters is generator start reliability and sustained run capability, not ride-through.
Automation runs on a restart clock. Conveyor systems, sortation, automated storage and retrieval, and the WMS behind them don't resume where they stopped. An unplanned stop means a controlled shutdown at best, and a recovery process measured in hours at worst - with product physically stranded on the line.
Retail runs on a transaction clock. Point of sale, payment authorisation and network connectivity fail immediately and visibly. The exposure is smaller per event and far more frequent, spread across every site in the estate.
One power event triggers all three. Most maintenance programmes are designed for only one.

What we maintain

Generator and transfer

The most important asset in a cold facility. Sets, transfer switches, fuel quality and fuel autonomy, and load bank testing that proves the set carries refrigeration and automation load together - not a light exercise run with the compressors offline.

Critical power

UPS plant protecting WMS servers, control systems, sortation controls and refrigeration controls, plus the distributed small-UPS estate across stores and back offices. Battery testing with trended impedance data.

Thermal

Server room and control room cooling, and the condensers and mechanical plant whose failure produces the same outcome as a power failure by a different route.

Peak season is decided in the off-season

A distribution center's least tolerant weeks are entirely predictable, and so is the fact that nobody will accept a maintenance shutdown during them. Which means the risk position for peak is set months earlier, by whether the work got done when it could have been.
We plan twelve months out against your peak calendar, grade every asset high, medium or low risk in a written Predictive Failure Analysis, and put remediation ahead of the ramp rather than into it.
For multi-site retail estates, we standardise the maintenance and battery replacement cycle across every location so the small units in the back office - the ones nobody walks past - get replaced on schedule instead of when a store can't take payment.

Equipment we service

Vendor agnostic across every make and model - Mitsubishi Electric (authorized service organization), Eaton and Powerware, APC, Toshiba, MGE, plus Alpha, BEST, Chloride, Cyberex, Deltec, Exide, IPM, PDI, SCI, Teledyne and United Power.

Retail and distribution power questions

How long can a cold storage facility survive a power outage?

It depends on room volume, product mass, insulation, door discipline and ambient conditions - a well-loaded, well-insulated room holds temperature far longer than an empty one. The number that matters is your specific room's measured time to reach the top of its allowable range, and most operators have never measured it. The generator strategy should be built on that figure, not an assumption.

Yes. Multi-site retail is a distributed estate problem - small units, unattended, invisible degradation. We inventory the estate, standardise the replacement cycle so it becomes a budget line, and identify the back-office closets running hot enough to be halving battery life.

Well ahead of peak. We plan twelve months against your peak calendar so remediation lands before the ramp, not during it.

15-minute technician reply, onsite within one to four hours, 24/7/365.